ExplorerMedical AIMedicine
Research PaperResearchia:202608.04053

TAVI-TEC: An AI-Based Tool for Procedural Planning of Transcatheter Aortic Valve Implantation

Alessandra Zerillo

Abstract

Computed tomography angiography (CTA) is crucial for preprocedural TAVI planning, providing the anatomical information required for prosthesis sizing and vascular access assessment. As the volume of TAVI procedure increases, improving efficiency and standardizing annotations is becoming essential in clinical practice. This study presents TAVI-TEC, a fully automated artificial intelligence-based framework integrated into a web based DICOM viewer for routine preoperative TAVI planning. Pre-procedu...

Submitted: August 4, 2026Subjects: Medicine; Medical AI

Description / Details

Computed tomography angiography (CTA) is crucial for preprocedural TAVI planning, providing the anatomical information required for prosthesis sizing and vascular access assessment. As the volume of TAVI procedure increases, improving efficiency and standardizing annotations is becoming essential in clinical practice. This study presents TAVI-TEC, a fully automated artificial intelligence-based framework integrated into a web based DICOM viewer for routine preoperative TAVI planning. Pre-procedural CTA scans from patients undergoing TAVI with SAPIEN 3 Ultra (S3U) prostheses were processed using a fully automated pipeline. Deep learning-based segmentation of cardiovascular structures, calcification detection, centerline extraction, landmark identification, and annular plane definition was implemented to quantify key annular and aortic root measurements and color-coded maps of lumen reduction and vessel diameter for vascular access. A multilayer perceptron classifier was trained to predict prosthesis size prior to the TAVI procedure. Results revealed that TAVI-TEC enabled pre-procedural measurements in approximately 2-6 min. Strong agreement with clinician-derived measurements was observed for annular area (coefficient of concordance, CCC = 0.934; interclass correlation coefficient, ICC = 0.935; R^2 = 0.881) and perimeter (CCC = 0.909; ICC = 0.909; R^2 = 0.854). The valve-size prediction model achieved 82% overall accuracy, with most misclassifications occurring between adjacent prosthesis sizes. Though further multicenter validation and extension to additional measurements and valve platforms are required, the TAVI-TEC methodology may reduce operator variability in pre-TAVI measurements and streamline the preoperative workflows of the Heart Team for decision-making.


Source: arXiv:2607.29243v1 - http://arxiv.org/abs/2607.29243v1 PDF: https://arxiv.org/pdf/2607.29243v1 Original Link: http://arxiv.org/abs/2607.29243v1

Please sign in to join the discussion.

No comments yet. Be the first to share your thoughts!

Access Paper
View Source PDF
Submission Info
Date:
Aug 4, 2026
Topic:
Medical AI
Area:
Medicine
Comments:
0
Bookmark