ExplorerMedical AIMedicine
Research PaperResearchia:202607.20043

Dataset-Origin Signatures and Shortcut Learning in Screening Mammography AI: A Cross-Dataset Case Study

Parham Hajishafiezahramini

Abstract

Reliable AI for screening mammography requires training data representative of the low cancer prevalence and subtle abnormalities found in screening populations. We examined whether supplementing such data with biopsy-confirmed cases from abnormal-enriched external datasets improves performance. Using the Newfoundland and Labrador Breast Screening Dataset (NLBSD) alongside CBIS-DDSM and CMMD, we evaluated an EfficientNet-B5 encoder initialized with Mammo-CLIP weights as a frozen linear probe und...

Submitted: July 20, 2026Subjects: Medicine; Medical AI

Description / Details

Reliable AI for screening mammography requires training data representative of the low cancer prevalence and subtle abnormalities found in screening populations. We examined whether supplementing such data with biopsy-confirmed cases from abnormal-enriched external datasets improves performance. Using the Newfoundland and Labrador Breast Screening Dataset (NLBSD) alongside CBIS-DDSM and CMMD, we evaluated an EfficientNet-B5 encoder initialized with Mammo-CLIP weights as a frozen linear probe under consistent preprocessing and patient-level splits. The NLBSD-only model achieved an AUC-ROC of 0.737 (95% CI [0.686, 0.785]). Adding external positive cases reduced performance in every configuration (AUC-ROC = 0.620--0.644; DeLong test, Holm-corrected p<0.05p < 0.05), with degradation increasing as additional sources were introduced. Domain-matched evaluation produced modest gains only when the training and test domains coincided, and no configuration surpassed the NLBSD-only model. As a diagnostic, we reframed the task as predicting each examination's dataset of origin. The datasets were separated almost perfectly despite identical preprocessing, indicating that dataset-specific characteristics strongly influence the learned representation. These findings show that naïvely pooling abnormal-enriched mammography datasets can introduce domain shift that outweighs the benefit of additional positive cases. Differences in acquisition, intensity mapping, and dataset construction persist after normalization, motivating domain-aware strategies for combining heterogeneous mammography datasets.


Source: arXiv:2607.15416v1 - http://arxiv.org/abs/2607.15416v1 PDF: https://arxiv.org/pdf/2607.15416v1 Original Link: http://arxiv.org/abs/2607.15416v1

Please sign in to join the discussion.

No comments yet. Be the first to share your thoughts!

Access Paper
View Source PDF
Submission Info
Date:
Jul 20, 2026
Topic:
Medical AI
Area:
Medicine
Comments:
0
Bookmark