ExplorerRoboticsRobotics
Research PaperResearchia:202608.11009

RoSE: A Robotic Soft Esophagus for Endoprosthetic Stent Testing

Dipankar Bhattacharya

Abstract

Soft robotic systems are well suited for developing devices for biomedical applications. A bio-mimicking robotic soft esophagus (RoSE) is developed as an in vitro testing device of endoprosthetic stents for dysphagia management. Endoprosthetic stent placement is an immediate and cost-effective therapy for dysphagia caused by malignant esophageal strictures from esophageal cancer. However, later stage complications, like stent migration, could weaken swallow efficacy in the esophagus. The stent r...

Submitted: August 11, 2026Subjects: Robotics; Robotics

Description / Details

Soft robotic systems are well suited for developing devices for biomedical applications. A bio-mimicking robotic soft esophagus (RoSE) is developed as an in vitro testing device of endoprosthetic stents for dysphagia management. Endoprosthetic stent placement is an immediate and cost-effective therapy for dysphagia caused by malignant esophageal strictures from esophageal cancer. However, later stage complications, like stent migration, could weaken swallow efficacy in the esophagus. The stent radial force (RF) on the esophageal wall is pivotal in avoiding stent migration. Due to limited randomized controlled trials in patients, stent design and stenting guidelines remain incomplete. To address this knowledge deficit, we investigate RoSE by implanting two stents (A and B) of different radial stiffness characteristics, to measure stent RF and its effect on migration. Endoscopic manometry under peristalsis is also performed to study the impact of stenting and stent dysfunction on intra-bolus pressure signatures (IBPSs) and swallowing efficacy. Each implanted stent undergoes experiments with varied peristalsis velocity, wavelength, and bolus concentrations. The results show that stiffer stent B has a higher RF, whereas stent A maintains a lower RF profile due to lesser stiffness. High RF is necessary to minimize migration under prolonged peristaltic contractions in RoSE. For manometry, stent A slightly increases IBPS, but stiffer stent B significantly decreases IBPS, especially for higher-concentration boluses. If a stiffer stent buckles, it can reduce swallow efficacy and cause recurrent dysphagia. RoSE is therefore an innovative soft robotic platform for testing endoprosthetic stents and addressing clinical challenges in stent evaluation.


Source: arXiv:2608.09891v1 - http://arxiv.org/abs/2608.09891v1 PDF: https://arxiv.org/pdf/2608.09891v1 Original Link: http://arxiv.org/abs/2608.09891v1

Please sign in to join the discussion.

No comments yet. Be the first to share your thoughts!

Access Paper
View Source PDF
Submission Info
Date:
Aug 11, 2026
Topic:
Robotics
Area:
Robotics
Comments:
0
Bookmark
RoSE: A Robotic Soft Esophagus for Endoprosthetic Stent Testing | Researchia