ExplorerRoboticsRobotics
Research PaperResearchia:202604.20077

DTEA: A Dual-Topology Elastic Actuator Enabling Real-Time Switching Between Series and Parallel Compliance

Vishal Ramesh

Abstract

Series and parallel elastic actuators offer complementary but mutually exclusive advantages, yet no existing actuator enables real-time transition between these topologies during operation. This paper presents a novel actuator design called the Dual-Topology Elastic Actuator (DTEA), which enables dynamic switching between SEA and PEA topologies during operation. A proof-of-concept prototype of the DTEA is developed to demonstrate the feasibility of the topology-switching mechanism. Experiments a...

Submitted: April 20, 2026Subjects: Robotics; Robotics

Description / Details

Series and parallel elastic actuators offer complementary but mutually exclusive advantages, yet no existing actuator enables real-time transition between these topologies during operation. This paper presents a novel actuator design called the Dual-Topology Elastic Actuator (DTEA), which enables dynamic switching between SEA and PEA topologies during operation. A proof-of-concept prototype of the DTEA is developed to demonstrate the feasibility of the topology-switching mechanism. Experiments are conducted to evaluate the robustness and timing of the switching mechanism under operational conditions. The actuator successfully performed 324 topology-switching cycles under load without damage, demonstrating the robustness of the mechanism. The measured switching time between SEA and PEA modes is under 33.33 ms. Additional experiments are conducted to characterize the static stiffness and disturbance rejection performance in both SEA and PEA modes. Static stiffness tests show that the PEA mode is 1.53x stiffer than the SEA mode, with KSEA = 5.57 +/- 0.02 Nm/rad and KPEA = 8.54 +/- 0.02 Nm/rad. Disturbance rejection experiments show that the mean peak deflection in SEA mode is 2.26x larger than in PEA mode (5.2 deg vs. 2.3 deg), while the mean settling time is 3.45x longer (1380 ms vs. 400 ms). The observed behaviors are consistent with the known characteristics of conventional SEA and PEA actuators, validating the functionality of both modes in the DTEA actuator.


Source: arXiv:2604.15865v1 - http://arxiv.org/abs/2604.15865v1 PDF: https://arxiv.org/pdf/2604.15865v1 Original Link: http://arxiv.org/abs/2604.15865v1

Please sign in to join the discussion.

No comments yet. Be the first to share your thoughts!

Access Paper
View Source PDF
Submission Info
Date:
Apr 20, 2026
Topic:
Robotics
Area:
Robotics
Comments:
0
Bookmark