ExplorerBiomedical EngineeringEngineering
Research PaperResearchia:202608.03039

Few-shot Deep Learning for Phase-Amplitude Aberration Correction in Transcranial Focused Ultrasound

Minju Seol

Abstract

Transcranial focused ultrasound (tFUS) is a non-invasive technique that delivers focused acoustic energy through the skull for neuromodulation and therapeutic applications. However, the heterogeneous structure of the skull induces complex, patient-specific phase and amplitude aberrations that distort the acoustic focus and deviate it from the intended target, compromising therapeutic efficacy and safety. Conventional time-reversal (TR) simulations can correct these aberrations but rely on comput...

Submitted: August 3, 2026Subjects: Engineering; Biomedical Engineering

Description / Details

Transcranial focused ultrasound (tFUS) is a non-invasive technique that delivers focused acoustic energy through the skull for neuromodulation and therapeutic applications. However, the heterogeneous structure of the skull induces complex, patient-specific phase and amplitude aberrations that distort the acoustic focus and deviate it from the intended target, compromising therapeutic efficacy and safety. Conventional time-reversal (TR) simulations can correct these aberrations but rely on computationally expensive full-wave solvers, making them impractical for real-time use and iterative treatment planning. We propose a few-shot deep surrogate framework that predicts per-element phase and amplitude corrections for a 96-element 3D phased-array transducer from patient CT images. A geometry-aware encoder extracts skull-path features shared across dedicated phase classification and amplitude regression branches, where phase periodicity is handled via circular expectation decoding. The framework is pretrained on diverse skull geometries and fine-tuned with only ten target points, enabling rapid adaptation to unseen patients without full patient-specific simulation. Evaluated via leave-one-out cross-validation across 12 skulls, it achieves a mean phase CMAE of 0.155 rad and amplitude rMAE of 9.089%, a focal centroid error of 0.467 mm, Dice score of 94.422%, and peak pressure ratio of 92.332%, with an approximately 2,535 times speedup over TR simulation. The code is available at https://github.com/Minju-Seol/fewshot-tfus-correction.


Source: arXiv:2607.29182v1 - http://arxiv.org/abs/2607.29182v1 PDF: https://arxiv.org/pdf/2607.29182v1 Original Link: http://arxiv.org/abs/2607.29182v1

Please sign in to join the discussion.

No comments yet. Be the first to share your thoughts!

Access Paper
View Source PDF
Submission Info
Date:
Aug 3, 2026
Topic:
Biomedical Engineering
Area:
Engineering
Comments:
0
Bookmark