Explorerโ€บBiomedical Engineeringโ€บEngineering
Research PaperResearchia:202610.19035

TransNSNet: A Transformer-Enhanced Multi-Scale Adversarial Framework for CT-to-PET Image Synthesis

Shaojun Li

Abstract

This study investigates CT-to-PET image synthesis using TransNSNet, a Transformer-enhanced multi-scale adversarial framework. A paired CT-PET dataset was curated from the public non-small cell lung cancer (NSCLC) Radiogenomics collection through patient screening, slice-level matching, preprocessing, and patient-level train-test separation. The proposed framework generates PET-like predictions at multiple spatial scales and applies coarse-to-fine reconstruction supervision, while TransPatchGAN i...

Submitted: October 19, 2026Subjects: Engineering; Biomedical Engineering

Description / Details

This study investigates CT-to-PET image synthesis using TransNSNet, a Transformer-enhanced multi-scale adversarial framework. A paired CT-PET dataset was curated from the public non-small cell lung cancer (NSCLC) Radiogenomics collection through patient screening, slice-level matching, preprocessing, and patient-level train-test separation. The proposed framework generates PET-like predictions at multiple spatial scales and applies coarse-to-fine reconstruction supervision, while TransPatchGAN introduces contextual feature interaction into adversarial evaluation. A progressive ablation study compares Pix2Pix, NSNet-Base, NSNet-D, and TransNSNet. Image-level performance was summarized over a fixed convergence window (epochs 80-101) from one training run per model. TransNSNet achieved the best mean value in nine of ten metrics, whereas NSNet-Base achieved the highest visual saliency-induced index. For fixed-fraction high-intensity regions, NSNet-D was marginally higher in slice-level recall and balanced accuracy, but the equal-weight patient-level values were nearly identical and the highest Dice values shifted to TransNSNet. These differences were small relative to between-patient variability. In the separate adaptive patient-level analysis (n=10), no pairwise model difference remained statistically significant after Holm correction. TransNSNet also had a substantially smaller parameter footprint than the original next-scale models. These findings indicate promising image-quality trends, but they do not establish statistical superiority or clinical validity; synthesized PET-like images should not be interpreted as substitutes for clinically acquired PET.


Source: arXiv:2610.23325v1 - http://arxiv.org/abs/2610.23325v1 PDF: https://arxiv.org/pdf/2610.23325v1 Original Link: http://arxiv.org/abs/2610.23325v1

Please sign in to join the discussion.

No comments yet. Be the first to share your thoughts!

Access Paper
View Source PDF
Submission Info
Date:
Oct 19, 2026
Topic:
Biomedical Engineering
Area:
Engineering
Comments:
0
Bookmark