ExplorerBiomedical EngineeringEngineering
Research PaperResearchia:202609.01039

OmniRAS: Standardizing Foundation Model Training and Evaluation in Robot-Assisted Surgery

Leonardo Borgioli

Abstract

Few foundation models exist for robot-assisted surgery, partly because large robotic-surgery video corpora are difficult to assemble and existing models are evaluated mostly on laparoscopic benchmarks. Further, most existing models are evaluated on a small set of public benchmarks, mostly focused on laparoscopic surgery. We present OmniRAS, a family of 1B- and 2B-parameter V-JEPA-2.1 encoders for robot-assisted surgery, and detail their training. First, we release two densely annotated robotic-c...

Submitted: September 1, 2026Subjects: Engineering; Biomedical Engineering

Description / Details

Few foundation models exist for robot-assisted surgery, partly because large robotic-surgery video corpora are difficult to assemble and existing models are evaluated mostly on laparoscopic benchmarks. Further, most existing models are evaluated on a small set of public benchmarks, mostly focused on laparoscopic surgery. We present OmniRAS, a family of 1B- and 2B-parameter V-JEPA-2.1 encoders for robot-assisted surgery, and detail their training. First, we release two densely annotated robotic-cholecystectomy datasets: OmniRAS-PR and a multi-label YT-Chole tool-verb-target task, the first triplet-style annotation for robotic cholecystectomy, together with splits, probe protocols, and an inter-rater study validating the shared phase ontology. Second, we document continued pretraining at up to 256 compute nodes with global batch 6,144 over 19 sources totaling approximately 2,650 hours of surgical video, 51% robotic, and analyze compute and data composition. Third, we evaluate against raw V-JEPA-2.1 and specialized surgical models on six tasks spanning triplet, phase, and step recognition, action segmentation, and detection, under frozen-encoder and final-four-block fine-tuning regimes. Across three seeds, this yields 254 downstream runs, including 109 with partial backbone fine-tuning. The best OmniRAS models achieve the strongest adapted results across all task families, while frozen differences are smaller.


Source: arXiv:2608.31048v1 - http://arxiv.org/abs/2608.31048v1 PDF: https://arxiv.org/pdf/2608.31048v1 Original Link: http://arxiv.org/abs/2608.31048v1

Please sign in to join the discussion.

No comments yet. Be the first to share your thoughts!

Access Paper
View Source PDF
Submission Info
Date:
Sep 1, 2026
Topic:
Biomedical Engineering
Area:
Engineering
Comments:
0
Bookmark
OmniRAS: Standardizing Foundation Model Training and Evaluation in Robot-Assisted Surgery | Researchia