ExplorerQuantum ComputingQuantum Physics
Research PaperResearchia:202607.21082

Scanless quantum Fourier-transform mid-infrared spectroscopy for rapid high-sensitivity hyperspectral mapping

Paul Gattinger

Abstract

Fourier-transform infrared (FTIR) spectroscopy is a well-established technique for qualitative and quantitative chemical analysis. Classical FTIR systems rely, however, on direct mid-infrared (mid-IR) scan-based time-domain measurements of coherence functions; thus, the signal-to-noise ratio and measurement speed are constrained by design. In this paper, we demonstrate a scanless quantum FTIR (sQFTIR) technique that exploits principles of metrology with entangled photons to circumvent the limita...

Submitted: July 21, 2026Subjects: Quantum Physics; Quantum Computing

Description / Details

Fourier-transform infrared (FTIR) spectroscopy is a well-established technique for qualitative and quantitative chemical analysis. Classical FTIR systems rely, however, on direct mid-infrared (mid-IR) scan-based time-domain measurements of coherence functions; thus, the signal-to-noise ratio and measurement speed are constrained by design. In this paper, we demonstrate a scanless quantum FTIR (sQFTIR) technique that exploits principles of metrology with entangled photons to circumvent the limitations inherent to classical FTIR systems. The approach exploits the interferometric nature of the sensing paradigm and relies on frequency-domain measurements performed with a static, low-gain nonlinear interferometer. A robust reconstruction algorithm is used to retrieve time-domain signals and reconstruct respective mid-infrared (mid-IR) spectra (3000 ~cm1^{-1} to 2380 ~cm1^{-1}) from near-IR measurements (approx. 780 ~nm to 820 ~nm). The suggested sQFTIR protocol eliminates the need for optical delay scanning and leverages inherent mapping between the related domains. In the theoretical section, we evaluate the intrinsic signal-to-noise advantage of the proposed method over conventional scan-based time-domain measurements; a difference of 26.8 dB (factor of 21.8) is demonstrated. Building on the enhanced sensitivity of the scheme, we demonstrate rapid sQFTIR-based hyperspectral imaging with a spatial resolution of 12.3 μm and a spectral resolution down to 8 ~cm1^{-1}. Hyperspectral mapping of human colon tissue, microplastics, and multilayer polymer samples composed of polypropylene and ethylene vinyl alcohol yield high-quality single-pixel spectra with acquisition times down to 10 ~ms.


Source: arXiv:2607.17964v1 - http://arxiv.org/abs/2607.17964v1 PDF: https://arxiv.org/pdf/2607.17964v1 Original Link: http://arxiv.org/abs/2607.17964v1

Please sign in to join the discussion.

No comments yet. Be the first to share your thoughts!

Access Paper
View Source PDF
Submission Info
Date:
Jul 21, 2026
Topic:
Quantum Computing
Area:
Quantum Physics
Comments:
0
Bookmark
Scanless quantum Fourier-transform mid-infrared spectroscopy for rapid high-sensitivity hyperspectral mapping | Researchia