ExplorerRoboticsRobotics
Research PaperResearchia:202607.09084

SonoRank: Towards Calibration-Free Real-Time Finger Flexion Detection from Forearm Ultrasound Sequences

Dean Zadok

Abstract

Powered prosthetic hands are frequently abandoned, largely due to the limited functionality of current devices that rely on surface electromyography (sEMG). Sonomyography (ultrasound) has emerged as a promising alternative, owing to its ability to observe muscle activity in real time and control a greater number of degrees of freedom. Yet, existing ultrasound-based methods require per-user fine-tuning, limiting their commercialization. We propose SonoRank, an important step towards calibration-f...

Submitted: July 9, 2026Subjects: Robotics; Robotics

Description / Details

Powered prosthetic hands are frequently abandoned, largely due to the limited functionality of current devices that rely on surface electromyography (sEMG). Sonomyography (ultrasound) has emerged as a promising alternative, owing to its ability to observe muscle activity in real time and control a greater number of degrees of freedom. Yet, existing ultrasound-based methods require per-user fine-tuning, limiting their commercialization. We propose SonoRank, an important step towards calibration-free finger flexion detection from forearm ultrasound video. SonoRank first learns to rank pairs of ultrasound sequences by their relative motion magnitude for each of the five fingers. The learned representations are then fine-tuned to classify whether each finger is actively flexing, using a rest reference that is captured at the beginning of the operation. Under 12-fold leave-one-subject-out cross-validation on a dataset of twelve subjects with synchronized kinematics, SonoRank achieves a 28% improvement in F1 score over direct classification baselines that skip the ranking stage. These results establish pairwise ranking as an effective pretraining signal for subject-independent control, bringing ultrasound-based prosthetics closer to practical, calibration-free deployment.


Source: arXiv:2607.07542v1 - http://arxiv.org/abs/2607.07542v1 PDF: https://arxiv.org/pdf/2607.07542v1 Original Link: http://arxiv.org/abs/2607.07542v1

Please sign in to join the discussion.

No comments yet. Be the first to share your thoughts!

Access Paper
View Source PDF
Submission Info
Date:
Jul 9, 2026
Topic:
Robotics
Area:
Robotics
Comments:
0
Bookmark
SonoRank: Towards Calibration-Free Real-Time Finger Flexion Detection from Forearm Ultrasound Sequences | Researchia