ExplorerRoboticsRobotics
Research PaperResearchia:202604.27077

Information-Theoretic Geometry Optimization and Physics-Aware Learning for Calibration-Free Magnetic Localization

Wenxuan Xie

Abstract

Wireless localization of permanent magnets enables occlusion-free guidance for medical interventions, yet its practical accuracy is fundamentally limited by two coupled challenges: the poor observability of conventional planar sensor arrays and the simulation-to-reality (Sim-to-Real) gap of learning-based estimators. To address these issues, this article presents a unified framework that combines information-theoretic sensor geometry optimization with physics-aware deep learning. First, a rigoro...

Submitted: April 27, 2026Subjects: Robotics; Robotics

Description / Details

Wireless localization of permanent magnets enables occlusion-free guidance for medical interventions, yet its practical accuracy is fundamentally limited by two coupled challenges: the poor observability of conventional planar sensor arrays and the simulation-to-reality (Sim-to-Real) gap of learning-based estimators. To address these issues, this article presents a unified framework that combines information-theoretic sensor geometry optimization with physics-aware deep learning. First, a rigorous Fisher Information Matrix (FIM)-based evaluation framework is established to quantify geometry-induced observability limitations. The results show that a staggered split-array topology provides a substantially stronger observability foundation for localization while remaining compatible with practical external deployment. Second, building on this optimized sensing configuration, we propose Phy-GAANet, a calibration-free estimator trained entirely on hardware-aware synthetic data. By incorporating Physics-Informed Features (PIF) for saturation modeling and Geometry-Aware Attention (GAA) for preserving cross-layer vector structure, the network effectively bridges the Sim-to-Real gap. Extensive real-world experiments demonstrate state-of-the-art performance, achieving a position error of 1.84 mm and an orientation error of 3.18 degrees at a refresh rate exceeding 270 Hz. The proposed method consistently outperforms classical Levenberg--Marquardt solvers and generic convolutional baselines, particularly in suppressing catastrophic outliers and maintaining robustness in challenging near-field boundary regions. Beyond the proposed network, the FIM-guided analysis also provides a framework for sensor geometry design in magnetic localization systems under practical deployment constraints.


Source: arXiv:2604.22526v1 - http://arxiv.org/abs/2604.22526v1 PDF: https://arxiv.org/pdf/2604.22526v1 Original Link: http://arxiv.org/abs/2604.22526v1

Please sign in to join the discussion.

No comments yet. Be the first to share your thoughts!

Access Paper
View Source PDF
Submission Info
Date:
Apr 27, 2026
Topic:
Robotics
Area:
Robotics
Comments:
0
Bookmark
Information-Theoretic Geometry Optimization and Physics-Aware Learning for Calibration-Free Magnetic Localization | Researchia